Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Error Codes



Error Codes

Error Code    FRU/Action
  
027601S0 027602S0 1. 10Base-T Adapter
027603S0 027604S0
POST Flash Main Sector
Checksum Failure
027605S0 027606S0 1. 10Base-T Adapter
027607S0 027608S0
027609S0 027610S0
027611S0 027612S0
Verify proper seating of the
DRAM SIMM on the adapter
027613S0 027614S0 1. 10Base-T Adapter
027615S0 027616S0
027617S0 027618S0
027619S0 027620S0
POST SRAM failure
027621S0 027622S0 1. 10Base-T Adapter
027623S0 027624S0
027625S0
027626S0 1. Verify correct cabling of Port 1
POST Ethernet Port 1 2. 10Base-T Adapter
External Loopback Failure
027627S0 1. Verify correct cabling of Port 2
POST Ethernet Port 2 2. 10Base-T Adapter
External Loopback Failure
027628S0 1. Verify correct cabling of Port 3
POST Ethernet Port 3 2. 10Base-T Adapter
External Loopback Failure
027629S0 1. Verify correct cabling of Port 4
POST Ethernet Port 4 2. 10Base-T Adapter
External Loopback Failure
027630S0 027631S0 1. 10Base-T Adapter
027632S0 027633S0
027691S0 027692S0 1. Run Setup and verify the adapter configuration
027693S0 027699S0 2. 10Base-T Adapter
  
027701S0 027702S0 1. 10Base2 Adapter
027703S0 027704S0
POST Flash Main Sector
Checksum Failure
027705S0 027706S0 1. 10Base2 Adapter
027707S0 027708S0
027709S0 027710S0
027711S0 027712S0
Verify proper seating of the
DRAM SIMM on the adapter
027713S0 027714S0 1. 10Base2 Adapter
027715S0 027716S0
027717S0 027718S0
027719S0 027720S0
POST SRAM failure
027721S0 027722S0 1. 10Base2 Adapter
027723S0 027724S0
027725S0
027726S0 1. Verify correct cabling of Port 1.
POST Ethernet Port 1 2. 10Base2 Adapter
External Loopback Failure
027727S0 1. Verify correct cabling of Port 2.
POST Ethernet Port 2 2. 10Base2 Adapter
External Loopback Failure
027728S0 1. Verify correct cabling of Port 3.
POST Ethernet Port 3 2. 10Base2 Adapter
External Loopback Failure
027729S0 1. Verify correct cabling of Port 4.
POST Ethernet Port 4 2. 10Base2 Adapter
External Loopback Failure
027730S0 027731S0 1. 10Base2 Adapter
027732S0 027733S0
027791S0 027792S0 1. Run Setup and verify the adapter configuration
027793S0 027799S0 2. 10Base2 Adapter


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.