|001|
+---+
IS THE SYSTEM PART OF A CLUSTER?
Yes No
| |
| +-+-+
| |002| Go to Step 004.
| +---+
+-+-+
|003|
+---+
Schedule maintenance with the customer. Shut down all systems related
to the cluster.
Run the hard disk test of the server diagnostics on the shared storage.
------------------------------------------------------------------------
+---+
|004|
+---+
- Power-off the server and all external devices.
- Check all cables and power cords.
- Set all display controls to the middle position.
- Boot the machine and watch for the ServeRAID adapter BIOS screen.
An example of a BIOS screen appears below.
+--------------------------------------------------------------------------------+
| |
| __________________________________ |
| IBM ServeRAID BIOS |
| Copyright IBM Corp. 1995,1998 |
| Ver: 3.00.12 08/14/1998 |
| __________________________________ |
| << Press Ctrl+I to access the Mini-Configuration Program. >> |
| |
| Initializing ServeRAID Controller 1 in Slot 1. |
| Power-on self-test can take up to 59 Second(s) - test Passed. |
| Drive configuration can take up to 6 Minute(s) 0 Second(s) - test Passed. |
| ServeRAID Firmware Version:2.82.00 |
| No logical drives found, none are installed. |
| Non-Disk SCSI Devices Found: CD-ROM 0, Tape 0, Removable-media 0, Other 1. |
| |
| BIOS not loaded no devices found - Installation stopped. |
| |
+--------------------------------------------------------------------------------+
DID THE BIOS SCREEN APPEAR?
Yes No
| |
| +-+-+
| |005| Try to download the ServeRAID BIOS to the adapter and reboot.
| +---+ If unsuccessful, replace the ServeRAID adapter.
+-+-+
|006|
+---+
- Note the status of the Power-On Self-Test.
DID THE POST INDICATE A PASSED STATUS?
Yes No
| |
| +-+-+
| |007| Refer to the Symptom-to-FRU Index for the following adapters:
| +---+
| - IBM PC ServeRAID Adapter (see Symptom-to-FRU Index)
| - IBM ServeRAID II Ultra SCSI Adapter (see Symptom-to-FRU Index)
| - IBM Netfinity ServeRAID Adapter 3H Ultra2 SCSI Adapter (see Symptom-to-FRU Index)
| - IBM Netfinity ServeRAID Adapter 3L Ultra2 SCSI Adapter (see Symptom-to-FRU Index)
+-+-+
|008|
+---+
- Note the Drive Configuration Status.
DID THE DRIVE CONFIGURATION STATUS INDICATE A PASSED STATUS?
Yes No
| |
| +-+-+
| |009| Refer to the Drive Configuration Conflict Resolution
| +---+ procedures for the following Adapters:
|
| - IBM PC ServeRAID Adapter (see Symptom-to-FRU Index)
| - IBM ServeRAID II Ultra SCSI Adapter (see Symptom-to-FRU Index)
| - IBM Netfinity ServeRAID Adapter 3H Ultra2 SCSI Adapter (see Symptom-to-FRU Index)
| - IBM Netfinity ServeRAID Adapter 3L Ultra2 SCSI Adapter (see Symptom-to-FRU Index)
+-+-+
|010|
+---+
Run the diagnostic program for the ServeRAID adapter. If
an Error Message indicates a failure, replace the adapter.
- or -
If the new adapter is installed and you still suspect a
problem, go to 'General Checkout' in the Hardware
Maintenance Manual for the server that the
adapter/controller is installed in.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.