Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Error Codes (8641-500)



Error Codes

Error Code    FRU/Action
0210XXXX 1. SCSI Hard Disk Drive
(Internal bus size unknown) 2. SCSI Adapter or the SCSI controller built
    into the system board.
0210XXXX 3. SCSI Cable
(External bus size unknown) 4. SCSI ID Switch (on some models)
  
0270xxxx 1. RAID Controller Error
      For explanation see RAID Diagnostic Error Codes
 
0271abcd 1. RAID Device Error
      a = Bay Number
      b = Channel Number
      c = Slot Number
      d = ID or PUN number of Device
      see SCSI/Non-SCSI Error Code Format
      For explanation see RAID Diagnostic Error Codes
  
02790XXX 02791XXX 1. Check power and reseat adapter
02792XXX 02793XXX 2. Ethernet PeerMaster Server Adapter
027906XX 027907XX
(Ethernet adapter POST
error)
02799XXX 1. Run Setup and verify the
(Communications to the     Ethernet PeerMaster Server Adapter
Ethernet PeerMaster Server     configuration
Adapter failed or the 2. Ethernet PeerMaster Server Adapter
adapter failed.
0279XXXX 1. Fast/Wide Streaming RAID Adapter/A
      (FRU P/N 06H3059) or Signal
      Pass Through Card (FRU P/N 06H3060)
  2. System Board
  3. Signal Pass Through Card (if installed)


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.