Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

ECA 080 - replace 8555 60MB disk



ECA 080 - replace 8555 60MB disk

 

Replacement 60MB Fixed Disk for 8555-061

PURPOSE:
This ECA provides a replacement 60MB Fixed Disk for affected 8555 model 061 systems.

PHYSICAL check:
Affected drives are known to have been shipped in all serial number ranges, however, not all systems will have the affected fixed disks. There are two methods available to determine if a drive is eligible for this ECA::
  1.  Run the "IBM PS/2 60MB Fixed Disk screening diskette."  This self-booting diskette will automatically check the  fixed disk in functioning systems, and tell the user if  the disk is affected.
     In Europe diskette the diskette also incorporates the  IBM 60MB Fixed Disk buffer test update. (ECA:055)

  2.  physically inspect the fixed disk. affected drives will  meet both of the following requirements:
      - 60MB Fixed Disk manufactured for IBM by Seagate,
      model ST-177i.
      - manufacturers date code x9035 thru x9045. This date code
      can be found on a small white label on the side of the
      drive. The disk must be removed from the system to read
      the label.


It is recommended that fixed disks determined eligible for this ECA be replaced before a failure is experienced.

ECA 055 is incorporated in the diskette

DETAIL:
A limited number of 60MB fixed disks shipped in 8555-061 systems may fail to spin at Power-on. This ECA provides on-site replacement of affected drives at no charge to the customer.

In an effort to minimize the risk of lost data due to a fixed disk failure, IBM has developed the "IBM PS/2 60MB Fixed Disk screening diskette." This diskette should be run on operational 8555 systems with a 60MB Fixed Disk installed. To use this diskette turn the system off, insert the diskette, then Power-ON the system. If the installed Fixed Disk is determined by the diskette to be affected, the customer should perform a fixed disk back-up and have the drive replaced.

If the Fixed Disk is not operative due to this problem, the 8555 will fail POST as follows:

- the system will display the memory count.
- the Fixed Disk light will blink approximately 9 times.
- the system will display a 10483 POST error.
- the Fixed Disk light will stay on for approximately one
minute, then begin blinking again. The 10483 error will
remain displayed.

If an affected Fixed Disk fails to spin after multiple Power-ON attempts, and the customer's data is not backed-up, the following procedure may restore temporary operation of the disk:
  1.  Remove the drive from the system. Place it on a sheet  of paper on a flat surface. The paper is used to avoid  scratching the flat surface. The drive should be resting  on its plastic slide mount rails, in its normal operating  position.
  2.  keeping the drive against the flat surface, rotate it in  a brisk clockwise/counter-clockwise motion. Do not hit,  bang, drop, or otherwise shock the fixed disk.
  3.  This rotating action should provide sufficient torque to  release any bound internal parts. Install the drive. If  POST completes successfully, the customer should back-up  the Fixed Disk immediately.


Replace the 60MB Fixed Disk with FRU P/N 6128282.

NOTEs:
Order parts through normal distribution.


Back to  Jump to TOP-of-PAGE
More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.