NETFINITY 7000: FRONT PANEL DISPLAYS UNREADABLE CHARACTERS
Subject: NETFINITY 7000: FRONT PANEL DISPLAYS UNREADABLE CHARACTERS
Updated Netfinity server RETAIN Tip:
Record number: H163143
Device: D/T8651
Model: M
Hit count: UHC00042
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O98/03/13
Date last altered: A98/09/15
Owning B.U.: USA
Abstract: NETFINITY 7000: FRONT PANEL DISPLAYS UNREADABLE CHARACTERS
SYMPTOM:
Incorrect or unreadable information is displayed on the Front
Panel after replacing the System Planar Board.
PROBLEM ISOLATION AIDS:
All of the following must be true for this TIP to apply:
- The System is a Netfinity 7000 Type 8651 Model RM0, RH0, TH0, TH0.
- The Symptoms started to occur immediately AFTER replacing the
System Planar board.
- Other than the Symptom described above, the System functions normally.
FIX:
Replace the Control Panel Card with FRU P/N 93H6052 using the
following procedure:
- Power down the Server, then remove the Power Cord.
- Loosen the two thumbscrews located at the back of the top cover.
- Remove the Top Cover by sliding the cover to the rear , then lift the front , then the rear.
- Disconnect the 20 conductor ribbon cable from J7 of the Control Panel Board.
- Remove the Two internal screws located at the top rear of
the LED Card Bracket Assembly, then remove the LED Card
Bracket Assembly (Refer to the IBM Netfinity Hardware
Maintenance Manual Supplement P/N 06J0791 page 102)
- Disconnect the following cables from the Control Panel
Board: - 2 conductor from J5 (to cover switch) - 26
conductor ribbon from J2 (to Power Backplane) - 40 conductor
ribbon cable from J1 (to Planer)
- Remove the 4 screws that secure the Control Panel Board to the chassis.
- Replace the Control Panel Board using normal parts replacement procedures.
- Reverse this procedure to complete the installation.
DETAIL:
The buffers used in the original Control Panel Card may cause
the Front Panel to display unreadable / incorrect characters.
This issue has no direct effect on the System's Server functions.