Record number: H166102
Device: D/T8680
Model: M
Hit count: UHC00019
Success count: USC0000
Publication code: PC50
Tip key: 015
Date created: O99/03/22
Date last altered: A99/03/31
Owning B.U.: USA
Abstract: REBUILDING MULTI DDD DRIVES ACROSS MORE THAN ONE ARRAY
TEXT:
REBUILDING MULTI DDD DRIVES ACROSS MORE THAN ONE ARRAY
SYMPTOM:
a Netfinity 7000-M10 server, Type 8680, any Model.
a Netfinity 7000 server, Type 8651, any Model.
a Netfinity 5500-M10 server, Type 8661, any Model.
a Netfinity 5500 server, Type 8660, any Model.
a Netfinity 5000 server, Type 8659, any Model.
a Netfinity 3500 server, Type 8644, any Model.
a Netfinity 3000 server, Type 8476, any Model.
a PC Server 704, Type 8650, any Model.
a PC Server 720, Type 8642, any Model.
a PC Server 520, Type 8641, any Model.
a PC Server 330, Type 8640, any Model.
a PC Server 325, Type 8639, any Model.
a PC Server 320, Type 8640, any Model.
a PC Server 315, Type 8638, any Model.
a PC Server 310, Type 8639, any Model.
FIX:
WORKAROUND:
In order to avoid this problem, do NOT replace the Channel 1, Drive ID 0 DDD drive first.
Rebuild the other drive (wherever it might be), and upon its successful conclusion rebuild the DDD drive at Channel 1, Drive ID 0.
DETAILS:
The default Hot Swap Rebuild program will look to rebuild to Channel 1, Drive ID 0.
If multiple logical drives are in a Critical state, then they all will attempt to rebuild to the Channel 1, Drive ID 0 at the same time.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.